Echion™ waterjet pumps
Simplifying service
Echion leverages the core technology of other Hypertherm intensifier-based pumps to deliver a high-performing pump in a smaller, industrial design.
The Echion family:
Echion 15, 30 & 50
Echion is a replacement of the basic HyPrecision Series. As well as the predecessor Echion is available in three power levels: Echion 15, 30 and 50.
The Echion product family is designed for an easy serviceability while delivering the same consistent quality, trouble-free operation, and reliability you have come to expect from Hypertherm products.
The heart of the Echion pump
The core of the Echion pump is a completely redesigned intensifier which contains the next evolution of Advanced Intensifier Technology™ (AIT). Leveraging many of the key attributes of AIT used in the HyPrecision Predictive pump line, the Echion intensifier allows users to reduce maintenance time and provides increased reliability.
Reduced Maintenance Time
Echion pumps include the next evolution of Hypertherm’s Advaced Intensifiert Technology. This technology eliminates soft, static high-pressure seals and incorporates industry-leading cartridge seal design, enabling rapid replacement of common consumables. Common service components are located at the front and center of the machine, equipped with quick-connect fittings, and an easy access bleed-down valve, to make maintenance faster, easier, and less expensive.
The Advanced Intensifier Technology:
In addition, Echion air-cooled pumps include a fully integrated heat exchanger, reducing the footprint of the system. The optional boost pump is also fully integrated to further reduce the system footprint and simplify integration.
Offered with closed-loop proportional pressure control and a color touchscreen as standard features, Echion pumps are designed to deliver an optimal end-user experience.
Pump model number | Echion 15 | Echion 30 | Echion 50 | ||||||
50 Hz | 60 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | ||||
GENERAL | |||||||||
Maximum output | 1.1 lpm (0.3 gpm) | 2.3 lpm (0.6 gpm) | 3.8 lpm (1.0 gpm) | ||||||
Maximum orifice | 0.18 mm (0.007″) | 0.28 mm (0.011″) | 0.35 mm (0.014″) | ||||||
Output pressure | Adjustable to 4,100 bar (60,000 psi) | ||||||||
Pressure control | Closed loop proportional pressure control – standard equipment | ||||||||
Bleed down valve | Air-actuated | ||||||||
PUMP POWER | |||||||||
Motor Power | 11.2 kW (15 HP) | 22.4 kW (30 HP) | 37.3 kW (50 HP) | ||||||
Voltage | 400 V | 208–230 V | 460 V | 400 V | 208–230 V | 460 V | 400 V | 208–230 V | 460 V |
Full load | 23 A | 45–41 A | 21 A | 44 A | 82–76 A | 38 A | 74 A | 136–124 A | 62 A |
Main breaker | 30 A | 60 A | 30 A | 60 A | 100 A | 60 A | 100 A | 200 A | 100 A |
Motor starter (options if more than 1 listed) |
Across-the-line | Wye-Delta Soft Start |
Across-the-line | Across-the-line Soft Start |
Wye-Delta Soft Start |
Wye-Delta | Wye-Delta Soft Start |
||
PHYSICAL | |||||||||
Width | 1,090 mm (43″) | ||||||||
Length | 1,350 mm (53″) | ||||||||
Height | 1,010 mm (40″) | ||||||||
Operating weight | 775 kg (1,700 lbs.) | 825 kg (1,850 lbs.) | 925 kg (2,050 lbs.) |